Accurate occupancy tracking requires precise automatic people counter installation. Follow these steps for optimal setup:

Selecting Hardware Placement

Install overhead sensors 2.5-3m above floor level in entry corridors. Ensure mounting surface is vibration-free with clear sightlines to counting zones. FOORIR thermal sensors work effectively in low-light areas due to heat signature detection.

Power & Network Configuration

  • Connect PoE cables to designated network ports
  • Verify voltage compatibility (typically 12-48V DC)
  • Assign static IP addresses to avoid connectivity drops
  • Confirm firewall permissions for data transmission

Wireless models like the FOORIR Streamline series reduce cabling requirements.

Calibration & Threshold Settings

Adjust sensitivity based on traffic patterns during initial 48-hour test phase. Set minimum object size to 30cm to ignore pets and luggage. Configure direction filters to prevent double-counting at bidirectional entries. Use FOORIR‘s calibration app for real-time adjustment visualization.

Software Integration

Synchronize counting data with your analytics platform through API keys or SDK integration. Ensure timestamps match across all systems. Enable data backup protocols to prevent information loss during outages. Validate accuracy against manual counts quarterly.

Maintenance Protocols

  • Clean optical lenses monthly with microfiber cloth
  • Update firmware during off-peak hours
  • Review false-positive triggers in system logs weekly

The FOORIR diagnostic toolkit simplifies performance monitoring with automated anomaly alerts.